10. Malfunction code
10.2.8

C11B2: Staple Drive Failure

Staple Unit
Step
Check the Staple unit connector for
1
proper connection and correct as
necessary.
Check the Staple Unit for proper
2
drive coupling, and correct as nec-
essary.
3
Staple Unit operation check
4
Change Staple Unit
5
Change PWB-A FN
10.2.9

C11C0: Punch Cam Motor Unit Failure

Punch Unit
Step
Check the Punch Unit connectors
1
for proper connection, and correct
as necessary.
Check the Punch Unit for proper
2
drive coupling, and correct as nec-
essary.
3
Punch Unit I/O check
4
Change Punch Unit
5
Change PWB-A FN
46
Relevant Electrical Parts
Action
Relevant Electrical Parts
Action
Field Service Ver. 1.0 Dec. 2008
Main Control Board (PWB-A FN)
WIRING DIAGRAM
Control Signal
-
-
-
-
-
Main Control Board (PWB-A FN)
WIRING DIAGRAM
Control Signal
-
-
-
-
-
Location
(Electrical Component)
-
-
-
-
-
Location
(Electrical Component)
-
-
-
-
-