Field Service Ver. 1.0 Dec. 2008
20. Remove four screws [23] and four
screws [24], and remove the Lower
Cover [25].
21. Remove the harness clamp and
unplug the connector [26].
22. Remove three screws [27], and
remove the Clincher/1 [28].
23. Remove the Staple Cartridge/1 [29].
24. Remove four screws [30], unplug the
connector, and remove the Stapler/1
[31].
NOTE
• To replace Clincher/2 and Stapler/2,
repeat steps 21 to 24.