5. OTHER MAINTENANCE ITEMS
[1]
7. To reinstall, reverse the order of removal.
8. Turn ON the power switch.
9. Select [SERVICE MODE] - [CLEAR DATA] - [PM COUNTER] and clear the counter
value of [TRAY1].
5.4.22

Tray 1 separation pad

1. Slide out the tray 1.
[1]
6. To reinstall, reverse the order of removal.
7. Turn ON the power switch.
8. Select [SERVICE MODE] - [CLEAR DATA] - [PM COUNTER] and clear the counter
value of [TRAY1].
50
[2]
A0XXF2E042DA
[1]
[2]
A0XXF2E040DA
A0XXF2E043DA
Field Service Ver. 2.0 Jun. 2010
6. Snap off the E-ring [1], and remove
the tray1 feed roller [2].
2. Press down the paper lifting plate.
3. Snap off the E-ring [2] from the feed
roller assy [1].
4. Slide the feed roller assy [1] to the
rear and pull it off the bushing at the
front.
5. Remove the tray 1 separation pad
[1].
NOTE
• Be careful not to lose spring at this
time.