Example
To configure the router port of IGMP proxy's upstream interface:
DGS-3420-28SC:admin#config igmp_proxy upstream_if vlan default router_ports add 3
Command: config igmp_proxy upstream_if vlan default router_ports add 3
Success.
DGS-3420-28SC:admin#
38-5
show igmp_proxy
Description
This command displays IGMP proxy configuration information or group information on the switch. The
display status item means group entry is determined by whether or not the chip is inserted.
Format
show igmp_proxy {group}
Parameters
group - (Optional) Specify the group information.
Note: If the group is not specified, the IGMP proxy configuration will be displayed.
Restrictions
None.
Example
To display IGMP proxy information:
DGS-3420-28SC:admin#show igmp_proxy
Command: show igmp_proxy
IGMP Proxy Global State
Upstream Interface
VLAN ID
Dynamic Router Ports
Static Router Ports
Unsolicited Report Interval
Source IP Address
: Enabled
: 1
: 1-4
: 5-6
: 10
: 0.0.0.0