D-Link xStack DGS-3420 Series Reference Manual page 397

Layer 2 managed stackable gigabit switch cli
Hide thumbs Also See for xStack DGS-3420 Series:
Table of Contents

Advertisement

xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
Example
To enable unidirectional link detection on port 1:
DGS-3420-28SC:admin# config duld ports 1 state enable
Commands: config duld ports 1 state enable
Success
DGS-3420-28SC:admin#
30-2
show duld ports
Description
This command is used to show unidirectional link detection information.
Format
show duld ports {<portlist>}
Parameters
ports - (Optional) Specify a range of ports to be display.
<portlist> - Enter the list of ports to be displayed here.
If no ports are specified, all the ports will be displayed.
Restrictions
None.
Example
To show ports 1-4 unidirectional link detection information:
DGS-3420-28SC:admin#config duld ports 1,2,4 state enable
Commands: config duld ports 1,2,4 state enable
Success
DGS-3420-28SC:admin#show duld ports 1-4
Command: show duld ports 1-4
Port
Admin State
-----
-----------
1
Enabled
2
Enabled
3
Enabled
4
Disabled
5
Enabled
Oper Status
Mode
-----------
--------
Enabled
Shutdown
Enabled
Normal
Enabled
Normal
Disabled
Normal
Enabled
Normal
Link Status
--------------
Bidirectional
RX Fault
TX Fault
Unknown
Link Down
392
Discovery Time(Sec)
-------------------
5
5
5
5
5

Advertisement