D-Link xStack DGS-3420 Series Reference Manual page 199

Layer 2 managed stackable gigabit switch cli
Hide thumbs Also See for xStack DGS-3420 Series:
Table of Contents

Advertisement

xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
between 1 and 4294967295.
ma - Specify the maintenance association name.
<string 22> - Specify the maintenance association name. The maximum length is 22 characters.
ma_index - Specify the maintenance association index.
<uint 1-4294967295> - Enter the maintenance association index value here. This value must
be between 1 and 4294967295.
state - Specify the MEP administrative state. The default is disable.
enable - Enable MEP.
disable - Disable MEP.
ccm - Specify the CCM transmission state. The default is disable.
enable - Enable the CCM transmission.
disable - Disable the CCM transmission.
pdu_priority - The 802.1p priority is set in the CCM and the LTM messages transmitted by the MEP.
The default value is 7.
<int 0-7> - Specify the value between 0 and 7.
fault_alarm - This is the control types of the fault alarms sent by the MEP. The default value is none.
all - All types of fault alarms will be sent.
mac_status - Only the fault alarms whose priority is equal to or higher than "Some Remote MEP
MAC Status Errors" are sent.
remote_ccm - Only the fault alarms whose priority is equal to or higher than "Some Remote
MEPs Down" are sent.
error_ccm - Only the fault alarms whose priority is equal to or higher than "Error CCM Received"
are sent.
xcon_ccm - Only the fault alarms whose priority is equal to or higher than "Cross-connect CCM
Received" are sent.
none - No fault alarm is sent.
alarm_time - Specify the time that a defect must exceed before the fault alarm can be sent. The unit
is centiseconds. The default value is 250.
<centisecond 250-1000> - Specify the time that a defect must exceed before the fault alarm can
be sent. The unit is centiseconds. The range is 250 to 1000.
alarm_reset_time - Specify the dormant duration time before a defect is triggered before the fault
can be re-alarmed. The unit is centiseconds. The default value is 1000.
<centisecond 250-1000> - Specify the dormant duration time before a defect is triggered before
the fault can be re-alarmed. The unit is centiseconds. The range is 250 to 1000.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.
Example
To configure the parameters of an MEP:
DGS-3420-28SC:admin#config cfm mep mepname mep1 state enable ccm enable
Command: config cfm mep mepname mep1 state enable ccm enable
Success.
DGS-3420-28SC:admin#
194