Chapter 29 Utility Commands - D-Link xStack DGS-3420 Series Reference Manual

Layer 2 managed stackable gigabit switch cli
Hide thumbs Also See for xStack DGS-3420 Series:
Table of Contents

Advertisement

xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
Chapter 29
download [firmware_fromTFTP [<ipaddr> | <ipv6addr> | <domain_name 255>] src_file
<path_filename 64> {[unit <unit_id> | all]} {dest_file <pathname>} {boot_up} | cfg_fromTFTP
[<ipaddr> | <ipv6addr> | <domain_name 255>] src_file <path_filename 64> {[unit <unit_id> | all]}
{[increment | dest_file <pathname>]}]
download cfg_fromRCP [{username <username>} {<ipaddr>} src_file <path_filename 64> | rcp:
<string 128>] {[unit <unit_id 1-12> | all]} {dest_file <pathname>}
download firmware_fromRCP [{username <username>} {<ipaddr>} src_file <path_filename 64> |
rcp: <string 128>] {[unit <unit_id 1-12> | all]} {dest_file <pathname>} {boot_up}
upload [cfg_toTFTP [<ipaddr> | <ipv6addr> | <domain_name 255>] dest_file <path_filename 64> {unit
<unit_id>} {src_file <pathname>} {[include | exclude | begin] <filter_string 80> {<filter_string 80>
{<filter_string 80>}} {[include | exclude | begin] <filter_string 80> {<filter_string 80> {<filter_string
80>}} {[include | exclude | begin] <filter_string 80> {<filter_string 80> {<filter_string 80>}}}}} |
log_toTFTP [<ipaddr> | <ipv6addr> | <domain_name 255>] dest_file <path_filename 64> |
attack_log_toTFTP [<ipaddr> | <ipv6addr> | <domain_name 255>] dest_file <path_filename 64>
{unit <unit_id>} | firmware_toTFTP [<ipaddr> | <ipv6addr> | <domain_name 255>] dest_file
<path_filename 64> {unit <unit_id>} {src_file <pathname>}]
upload attack_log_toRCP [{username <username>} {<ipaddr>} dest_file <path_filename 64> | rcp:
<string 128>] {unit <unit_id 1-12>}
upload cfg_toRCP [{username <username>} {<ipaddr>} dest_file <path_filename 64> | rcp: <string
128>] {unit <unit_id 1-12>} {src_file <pathname>} {[include | exclude | begin] <filter_string 80>
{<filter_string 80> {<filter_string 80>}} {[include | exclude | begin] <filter_string 80> {<filter_string
80> {<filter_string 80>}} {[include | exclude | begin] <filter_string 80> {<filter_string 80>
{<filter_string 80>}}}}}
upload firmware_toRCP [{username <username>} {<ipaddr>} dest_file <path_filename 64> | rcp:
<string 128>] {unit <unit_id 1-12>} {src_file <pathname>}
upload log_toRCP [{username <username>} {<ipaddr>} dest_file <path_filename 64> | rcp: <string
128>]
config firmware image {unit <unit_id>} <pathname> boot_up
config configuration {unit <unit_id>} <pathname> [boot_up | active]
show config [effective | modified | current_config | boot_up | file <pathname>] {[include | exclude |
begin] <filter_string 80> {<filter_string 80> {<filter_string 80>}} {[include | exclude | begin]
<filter_string 80> {<filter_string 80> {<filter_string 80>}} {[include | exclude | begin] <filter_string
80> {<filter_string 80> {<filter_string 80>}}}}}
show boot_file
config rcp server {ipaddress <ipaddr> | username <username>}
config rcp server clear [ipaddr | username | both]
show rcp server
ping [<ipaddr> | <domain_name 255>] {times <value 1-255> | timeout <sec 1-99> | source_ip
<ipaddr>}
ping6 [<ipv6addr> | <domain_name 255>] {times <value 1-255> | size <value 1-6000> | timeout <sec
1-99> | source_ip <ipv6addr>}
traceroute [<ipaddr> | <domain_name 255>] {ttl <value 1-60> | port <value 30000-64900> | timeout
<sec 1-65535> | probe <value 1-9>}
traceroute6 [<ipv6addr> | <domain_name 255>] {ttl <value 1-60> | port <value 30000-64900> |
timeout <sec 1-65535> | probe <value 1-9>}
telnet [<ipaddr> | <domain_name 255> | <ipv6addr>] {tcp_port <value 1-65535>}
config telnet source_ipif [<ipif_name 12> {<ipaddr> | <ipv6addr>} | none]
show telnet source_ipif
Utility Commands
979

Advertisement

Table of Contents
loading

Table of Contents