xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
Format
create sflow analyzer_server <value 1-4> owner<name 16> {timeout [<sec 1-2000000> | infinite]
| collectoraddress [<ipaddr> | <ipv6addr>] | collectorport <udp_port_number 1-65535> |
maxdatagramsize <value 300-1400>}
Parameters
<value 1-4> - Specify a value between 1 and 4.
owner - Specify the entity making use of this sflow analyzer server. When owner is set or modified,
the timeout value will become 400 automatically.
<name 16> - Specify the entity making use of this sflow analyzer server. When owner is set or
modified, the timeout value will become 400 automatically.
timeout - (Optional) Specify the length of time before the server is timed out. When the analyzer
server times out, all of the flow samplers and counter pollers associated with this analyzer server
will be deleted. If not specified, its default value is 400. If it is specified as infinite, the server will
never time out.
<sec 1-2000000> - Specify the time out value, in seconds, between 1 and 2000000.
infinite - Specify to never time out.
collectoraddress - (Optional) Specify the IP address of the analyzer server.
<ipaddr> - Specify the IP address of the analyzer server. If not specified, the address will be
0.0.0.0, which means that the entry will be inactive.
<ipv6addr> - Specify the IPv6 address of the analyzer server.
collectorport - (Optional) Specify the destination UDP port for sending the sFlow datagrams.
<udp_port_number 1-65535> - Specify the destination UDP port for sending the sFlow
datagrams. If not specified, the default value is 6343.
maxdatagramsize - (Optional) Specify the maximum number of data bytes that can be packed in a
single sample datagram.
<value 300-1400> - Specify the maximum number of data bytes that can be packed in a single
sample datagram. If not specified, the default value is 1400.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example
To create an sFlow analyzer server named "monitor":
DGS-3420-28SC:admin#create sflow analyzer_server 1 owner monitor
Command: create sflow analyzer_server 1 owner monitor
Success.
DGS-3420-28SC:admin#