Avaya DEFINITY Server CSI Maintenance Manual page 1645

Table of Contents

Advertisement

TBRI-TRK (TN2185 ISDN Trunk-Side BRI)
Hardware Error Log Entries and Test to Clear
Values
TBRI-TRK Error Log Entries
Table 481.
Error
Aux
Type
Data
1
0
0
513 (a)
1793 (b)
8, 9
3073 (c)
3585 (d)
3841 (e)
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Notes:
a. The far-end has reported that this channel is not administered. The trunks
are placed in the out-of-service state.
b. The Signaling link is down. See the following Aux Data explanation:
— Aux data 8 indicates the Signaling Link is down.
— Aux data 9 indicates the Port is out of service.
c. The Service State Audit failed. The test will be run every 15 minutes until it
passes.
d. Unexpected Restart message; this error causes no action and is logged
only.
e. B-Channel Rejection Event; this action causes the Service State Audit, the
Call State Audit, and the Test Call Audit to be executed.
555-233-119
Associated Test
Any
Any
Service State Audit
WARNING
(Test #256)
WARNING
Service State Audit
(Test #256)
WARNING
Alarm
On/Off
Level
Board
Any
test Port UCSSPP sh r 1
OFF
OFF
OFF
Issue 5 October 2002
Test to Clear Value