Avaya DEFINITY Server CSI Maintenance Manual page 1623

Table of Contents

Advertisement

TBRI-BD (TN2185 ISDN Trunk-Side BRI)
Table 469. TEST #595 LAN Receive Parity Error Counter Test
Error
Test
Code
Result
2000
ABORT
2100
ABORT
2012
ABORT
1-10
FAIL
PASS
555-233-119
Description/ Recommendation
Response to the test was not received from the circuit pack within the
allowable time period.
1. If the test aborts repeatedly a maximum of 5 times, reset the circuit
pack via the busyout board PCSS and reset board PCSS
commands.
2. If the test aborts again, replace the circuit pack.
Could not allocate the necessary system resources to run this test.
Internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The circuit pack is still detecting errors of this type. The error code indicates
the value of the on-board error counter.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, verify the validity of the Packet Bus. Run the
Packet Bus maintenance test with the test pkt P long command.
3. If the Packet Bus test passes, check the validity of the circuit pack.
Execute a test that involves data transmission onto the Packet Bus. For
example, the test port PCSSpp command may use the connectivity
tests of the BRI-PORT maintenance object. If the test fails, refer to the
repair procedures; otherwise, proceed to the next step.
4. Other circuit packs on the Packet Bus may be causing of the parity
error. Use the display errors command to check the Error Log for
alarmed other circuit packs. Resolve any alarms for other circuit packs
as well. Rerun the LAN Receive Parity Error Counter Test (#595).
No errors detected.
Continued on next page
Issue 5 October 2002
1623

Hide quick links:

Advertisement

Table of Contents
loading