TBRI-PT (TN2185 ISDN Trunk-Side BRI Port)
Table 470. TBRI-PT Error Log Entries — Continued
Error
Aux
Type
Data
1793 (j)
2049 (k)
2305 (l)
3073 (m)
3585 (n)
3586 (o)
3587 (p)
3588 (q)
46223
3589 (r)
3590 (s)
46211
3591 (t)
3592 (u)
3841 to
3942 (v)
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2.
The far-end switch changed the ISDN service state. This may be a temporary condition.
Notes:
a. Loss of continuity of Layer 1 to the far-end. It is assumed that Layer 1
remains active, even when both B-Channels are idle.
This test determines whether Layer 1 is active or not. If Layer 1 is not
active, the test attempts to activate it. If Layer 1 cannot be activated, the
port is taken out of service, and the test fails.
b. The D-Channel failed at Layer 2. Expiration of this timer indicates that
attempts to bring the failed link back into service have not succeeded and
some recovery actions should be taken on the associated B-Channels.
Upon expiration, associated in-service B-channels are put in the
out-of-service/far end state.
555-233-119
Associated Test
BRI Port Local
MINOR
TDM Looparound
Test (#619)
MINOR
Layer 3 Query
MINOR
(#1243)
Slip Query Test
MINOR
(#1244)
Receive FIFO
Log Only
Overflow (TDM
D-Channel)
Alarm
On/Off
Level
Board
ON
OFF
OFF
OFF
ON
Issue 5 October 2002
Test to Clear Value
Continued on next page