Avaya DEFINITY Server CSI Maintenance Manual page 1634

Table of Contents

Advertisement

Maintenance Objects
Table 474. TEST #618 BRI Port Local LAN Loop Around
Error
Test
Code
Result
1015
ABORT
1141
ABORT
2012
ABORT
2100
FAIL
PASS
BRI Port Local TDM Looparound Test (#619)
This test is conditionally destructive.
This test verifies the connectivity of a BRI port across the TDM Bus. It aborts if
calls associated with the port are in progress. Failure of this test indicates an
on-board fault associated with the port hardware on the circuit pack.
1634
Issue 5 October 2002
Description/ Recommendation
The port is not out-of-service.
1. Use the status bri-port PCSSpp command to determine the status of
the port.
2. If it is in use, wait until it is idle, and then use the busyout port
PCSSpp command to place it in the out-of-service state and repeat this
test.
!
CAUTION:
Since the busyout command is destructive, execution of this
command prior to the port being idle causes all calls
associated with the BRI port to be torn down.
The PKT-INT is out-of-service.
1. Follow the repair procedures for the PKT-INT.
2. Run the test port long PCSSpp command and verify the repair by
viewing the results of the BRI Port Local LAN Looparound Test (#618).
Internal System Error.
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The Looparound Test failed.
1. If the test fails repeatedly, attempt to reset the circuit pack with the
busyout board PCSS and the reset board PCSS commands if the
other ports on the board are not in use.
2. If the test fails again, execute test pkt P.
3. If the tests in Step 2 pass, the problem is local to the BRI board.
Replace the trunk circuit pack.
The BRI Port Local LAN Looparound Test passed.
Continued on next page

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents