Barco FSN Series User Manual page 250

Table of Contents

Advertisement

6. System Setup
Output Test Patterns
lìíéìí=qÉëí=m~ííÉêåë
FSN Series system setup: Step 7 (optional)
In this procedure, you can display test patterns on selected system outputs (or all system
7
outputs), typically for purposes of setting up external devices.
Use the following steps to select and display output test patterns:
1.
2.
3.
4.
250
Prerequisite — Ensure that you are familiar with the Output Test Patterns
Menu . In Chapter 5, refer to the "
page 182.
In the Menu Bar , press {System} to access the System Menu .
Press {Output Test Patterns} to display the Output Test Patterns Menu .
To display a test pattern on one output:
a.
Press the desired output connector in the Rear I/O View on the left side
of the menu.
b.
Press the desired test pattern in the matrix on the right side of the menu.
c.
Press {Raster Box} to enable or disable the raster box as desired.
d.
When complete, press {Off} to turn the test pattern off.
Note
Remember that you can set a different test pattern on each
output.
To display a test pattern on all outputs:
a.
Press {Select All Outputs} .
b.
Press the desired test pattern in the matrix on the right side of the menu.
c.
Press {Raster Box} to enable or disable the raster box as desired.
d.
When complete, press {All Off} .
Important
Ensure that you press {All Off} after you have finished using
any output test pattern.
Output Test Patterns Menu