Ddm Rx Power Threshold Settings - Panasonic GA-ML Series Manual

Hide thumbs Also See for GA-ML Series:
Table of Contents

Advertisement

10.2.6

DDM RX Power Threshold Settings

Use the following window to implement the settings on the DDM RX
power threshold on the port specified and to display its settings.
Choose DDM > DDM RX Power Threshold Settings to display the
following window.
Figure 10-7 DDM RX Power Threshold Settings
In the section of DDM RX Power Threshold Settings, you can configure
the following parameters.
Parameter
Port
Action
Type
Power Unit
Value
Click Apply to reflect the change.
10 OAM (Operations, Administration & Management)
10.2.6 DDM RX Power Threshold Settings
Choose the port you use.
Choose an action to be executed. The options available
are Add and Delete.
Choose the type of RX power threshold. The options
available are Low Alarm, Low Warning, High Alarm
and High Warning.
Choose the power unit. The options available are mW
and dBm.
Enter the threshold.
• When specifying the threshold in mW, the range is
from 0 to 6.5535 (mW).
• When specifying the threshold in dBm, the range is
from -40 to 8.1647 (dBm).
Overview
375