Soldering splice connectors is optional. To solder splice connectors:
1. Position the leads, so one overlaps the other. See Figure 3-19.
Figure 3-19
Positioning the Leads
2. Secure the leads with a commercially available clip and hand tool. See Figure 3-20.
Figure 3-20
Securing the Leads With a Clip
3. Use a suitable electronic soldering iron to heat the wires. Apply the solder to the heated
wire and clip (not to the soldering iron) allowing sufficient solder flow into the splice joint.