Detroit Diesel DDEC VI Application And Installation page 200

Table of Contents

Advertisement

INPUTS AND OUTPUTS
4.3.12
LOW COOLANT LEVEL LAMP
This digital output is switched to ground when a low coolant level fault is detected.
NOTE:
This function is optional.
Installation
This digital output circuit is designed to sink no more than 250 mA (DC) current.
The Low Coolant Level Lamp is wired to pin 3/10 of the CPC.
Programming Requirements and Flexibility
The options for this digital output are listed in Table 4-38.
Parameter
Parameter
Group
3 10 DO
35
Selection
3 10
35
DO Fault
Detection
* Not supported in NAFTA
Table 4-38
Coolant Level Low Lamp Programming Options
4-40
Setting
0 – Disabled
1 – Air Filter Lamp*
2 – AGS2 Transmission Temp
4 – Coolant Level
Indication Lamp
Low Lamp
3 – Battery Voltage Low Lamp
4 – Coolant Level Low Lamp
5 – FUSO Retarder Control 1*
0 — Disabled
1 — Enabled
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
Options
Default
0 – Disabled
0 – Disabled
All information subject to change without notice. (Rev. 01/07)