HARDWARE AND WIRING
3.7.3
DPF REGENERATION LAMP
This lamp is controlled by DDEC VI.
The DPF Regeneration Lamp remains ON when
□ Stationary regeneration is required.
□ At the start of every ignition cycle, the lamp turns ON for
The DPF Regeneration Lamp flashes when a stationary regeneration is required immediately. If
the lamp flashing is ignored, derate and/or shutdown could occur.
DPF Regeneration Lamp Requirements and Guidelines
The following requirements and guidelines apply to the DPF Regeneration Lamp:
□ The DPF Regeneration Lamp is required.
□ A 12 volt light of less than 0.25 A (DC) is required depending on the ignition source.
Digital output circuits are designed to sink no more than 0.25 A (DC) current.
□ The DPF Regeneration Lamp must be integrated into the instrument panel or placed in
clear view of the vehicle operator.
□ The lens color must be amber.
□ This output is wired to pin 1/5 of the CPC.
□ This lamp can be multiplexed on J1939.
□ The DPF Regeneration symbol shown above is required.
Programming Requirements and Flexibility
The parameters for the DPF Regeneration Lamp are listed in Table 3-110.
Parameter
Parameter
Group
1 05 Fault
35
Detection
46
DPF Lamp Config
Table 3-110
DPF Regeneration Lamp Options
3-110
approximately five (5) seconds (a bulb check).
Options
0 = Disabled
1 = Enabled
0 = Hardwired
1 = J1939 PTC1
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
Default
Access
0 = Disabled
VEPS, DRS
0 = Hardwired
VEPS, DRS
All information subject to change without notice. (Rev. 01/07)