Detroit Diesel DDEC VI Application And Installation page 352

Table of Contents

Advertisement

FEATURES
Parameter
Parameters
Group
Max Road
7
Speed in PTO
Mode
Set Coast
7
Switch PTO
Set Speed
Set Coast
7
Max PTO
Torque
Resume
7
Accel Sw
PTO Set Spd
Resume
7
Accel Max
PTO Torque
PTO Ramp
7
Rate
Table 5-74
Cruise Switch PTO Parameters (2 of 2)
5.25.3
REMOTE PTO — PREPROGRAMMED SET SPEEDS
The Remote PTO will override the Cab PTO mode when the Remote PTO Switch input on the
CPC (2/9) is grounded. The active throttle will override Remote PTO if "PTO Throttle Override"
is enabled.
Remote PTO speed is disabled for any of the following:
□ Turning the Remote PTO switch off for more than two seconds
□ Vehicle speed is greater than Max Vehicle Speed in PTO (programmable – default 10 km/h)
□ VSS fault
□ Clutch Released Pedal or Service Brake Pedal are pressed (if configured)
□ Park Brake is OFF (if configured)
□ Park Brake or Service Brake is applied (PTO Dropout Serv Brk Prk Brk)
□ Cruise Switch fault
□ Clutch Pedal is pressed (PTO dropout on clutch enabled)
□ Optimized Idle is active
5-140
Description
Sets the max vehicle
speed over which PTO is
disabled
Sets the initial speed
when the Set/Coast
Switch is used to enable
Cab PTO
Sets the max engine
torque that becomes
active once the Set/Coast
Switch is activated
Sets the initial speed
when the Resume/Accel
Switch is used to enable
Cab PTO
Sets the max engine
torque that becomes
active once the
Resume/Accel Switch
is activated
Sets the rate of increase
or decrease.
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
Options
Default
0 – 128 km/h
10 km/h
0 — 3000 RPM
500 RPM
0 – 5000 Nm
5000 Nm
0 — 3000 RPM
500 RPM
0 – 5000 Nm
5000 Nm
25 – 2500 RPM/sec
200 RPM/sec
All information subject to change without notice. (Rev. 01/07)
Access
DDDL
7.0, DRS,
VEPS
DDDL
7.0, DRS,
VEPS
DDDL
7.0, DRS,
VEPS
DDDL
7.0, DRS,
VEPS
DDDL
7.0, DRS,
VEPS
DDDL
7.0, DRS,
VEPS

Hide quick links: