Detroit Diesel DDEC VI Application And Installation page 192

Table of Contents

Advertisement

INPUTS AND OUTPUTS
4.3.3
AGS2 TRANS TEMP LAMP
This digital output is used for non-multiplexed applications with the AGS2 transmission.
Installation
This digital output circuit is designed to sink no more that 250 mA (DC) current.
The AGS2 Transmission Temp Indication Lamp is wired to pin 3/10 of the CPC.
Programming Requirements and Flexibility
The options for this digital output are listed in Table 4-30.
Parameter
Parameter
Group
3 10 DO
35
Selection
3 10
35
DO Fault
Detection
* Not supported in NAFTA
Table 4-30
AGS2 Transmission Temp Indication Lamp Programming Options
4.3.4
AMBER WARNING LAMP
The Amber Warning Lamp is illuminated for all active faults. The AWL will also flash when
an engine shutdown occurs.
Installation
This digital output circuit is designed to sink no more than 250 mA (DC) current.
The AWL is wired to pin 2/10 of the CPC.
NOTE:
This digital output is REQUIRED.
4-32
Setting
0 – Disabled
1 – Air Filter Lamp*
2 – AGS2 Transmission
2 – AGS2
Temp Indication Lamp
3 – Battery Voltage Low
Transmission Temp
Indication Lamp
Lamp
4 – Coolant Level Low Lamp
5 – FUSO Retarder Control
1*
0 – Disabled
1 – Enable
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
Options
Default
0 – Disabled
0 – Disabled
All information subject to change without notice. (Rev. 01/07)