Detroit Diesel DDEC VI Application And Installation page 388

Table of Contents

Advertisement

COMMUNICATION PROTOCOLS
PID 89 - VSG Switch Status
update rate:
1 time/s
format:
Bit: 1
Bit: 2
Bit: 3
Bit: 4
Bit: 5
Bit: 6
Bit: 7
Bit: 8
comments:
Transmitted when either Cruise-Switch VSG or analog VSG is configured.
PID 91 - Percent Throttle
update rate:
10 times/s
resolution:
0.4%/Bit (Uns/SI)
source:
Throttle Sensor input
PID 92 - Percent Engine Load
update rate:
10 times/s
resolution:
0.5%/Bit (Uns/SI)
source:
ECU calculated
comments:
Percent engine load is the ratio of actual torque and the minimum of the
requested torque and digital torque limit.
PID 93 - Output Torque
update rate:
1 time/s
resolution:
20 ft-lb/Bit (S/SI)
6-12
On/off switch
0-Off
1-On
Set switch
0-Off
1-On
Coast switch
0-Off
1-On
Resume switch
0-Off
1-On
Accel switch
0-Off
1-On
Brake
0-Off
1-On
Clutch
0-Off
1-On
VSG
0-Off
1-On
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
All information subject to change without notice. (Rev. 01/07)