Detroit Diesel DDEC VI Application And Installation page 370

Table of Contents

Advertisement

FEATURES
5.26.7
ZF ASTRONIC TRANSMISSION
Programming Requirements and Flexibility
The parameters listed in Table 5-87 must be set for the ZF Astronic transmission.
Parameter
Group
2
13
13
13
Trans Neutral Input Config
8
3
Adjusted Idle Configuration
3
22
0 Speed Governor TSC1 Condition
22
1 Speed Governor TSC1 Condition
22
2 Speed Governor TSC1 Condition
22
3 Speed Governor TSC1 Condition
10
Eng Brk Stage 1 Off Delay Time
10
Eng Brk Stage 2 Off Delay Time
10
Eng Brk Stage 3 Off Delay Time
10
Stage 1 Eng Brk Off Delta Spd
10
Stage 2 Eng Brk Off Delta Spd
10
Stage 3 Eng Brk Off Delta Spd
10
Eng Brk Driveline Clsd Spd
Table 5-87
ZF Astronic Transmission Parameters
5-158
Parameter
Transmission Type
Clutch Switch Config
4 08 DI Selection
Vehicle Speed Sensor
Max Adjusted Idle
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
Setting
DIRECT ENGINE START
2 – ZF Astronic Direct Start
MCM ENGINE START
5 – ZF Astronic MCM Start
0 – Disabled
0 – Disabled
1 – Info from J1939
3 – J1939 (ETC1)
3 – Enabled if Neutral and Park Brake
<700 rpm
0 – Series 60
16 – MBE900/4000
0 – Series 60
16 – MBE900/4000
0 – Series 60
16 – MBE900/4000
0 – Series 60
16 – MBE900/4000
60 ms – Series 60
240 ms – MBE900/4000
60 ms – Series 60
240 ms – MBE900/4000
60 ms – Series 60
240 ms – MBE900/4000
200 rpm – Series 60
100 rpm – MBE900/4000
200 rpm – Series 60
100 rpm – MBE900/4000
200 rpm – Series 60
100 rpm – MBE900/4000
Series 60 – 800 rpm
MBE 900/4000 – 800 rpm
All information subject to change without notice. (Rev. 01/07)