Detroit Diesel DDEC VI Application And Installation page 268

Table of Contents

Advertisement

FEATURES
The CPC options for the single-speed fan – Type 4 are listed in Table 5-34.
Parameter
Parameter
Group
AC Fan Vehicle
19
Speed Enable
AC Fan Vehicle
19
Speed Thresh
Eng Brake Enable
19
Auto Fan
PTO Enable Auto
19
Fan Activation
Air Condition
19
Enable Auto Fan
J1939 Fan
19
Request Enable
19
Fan AC Hold Time
19
Hold Time Fan
Mode of AC
6
Status Input
Table 5-34
Single-speed Fan – Type 4 CPC Options
5-56
Description
Enables/disables the
road speed threshold
for AC fan.
Road speed threshold
above which the A/C
fan request is not using
the hold time
Enables/disables turning
on the fan with engine
brakes.
Enables/disables turning
on the fan when the
PTO is active.
Enables/disables turning
on the fan when the air
conditioning is on.
Enables the fan based
on a J1939 CM1 fan
request.
Minimum fan on time
for AC
Minimum fan on time
0 = Disable
1 = AC Active Closed
Defines type of input
2 = AC Active Open
for A/C switch
3 = LIM Active Closed
4 = LIM Active Open
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
Options
Default
0 = Disable
0 = Disable
1 = Enable
0 – 250 km/h
32 km/h
0 = Disable
0 = Disable
1 = Enable
0 = Disable
0 = Disable
1 = Enable
0 = Disable
1 = Enable
1 = Enable
0 = Disable
0 = Disable
1 = Enable
0–600 sec
180 sec
0–600 sec
10 sec
2 = AC
Active Open
All information subject to change without notice. (Rev. 01/07)