5.23.2
INSTALLATION
The Starter Lockout output circuit drives a normally closed relay, which interrupts the starting
signal when the output has been activated. See Figure 5-29.
Figure 5-29
Starter Lockout
5.23.3
PROGRAMMING REQUIREMENTS AND FLEXIBILITY
Starter Lockout may be enabled or disabled as listed in Table 5-71 with VEPS or DRS.
Parameter
Parameter
Group
35
3 17 DO Selection
3 17 DO Fault
35
Detection
* Not supported in NAFTA
Table 5-71
Starter Lockout
5-130
Setting
1 – Enable Starter Lockout
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
Options
0 – Disabled
1 – Enable Starter Lockout
2 – Enable kick down output*
3 – Not used
4 – Optimized Idle Alarm
5 – Split Valve*
6 – Starter Lockout + AGS2
7 – Engine brke disabled for
over speed*
0 = Enable
1 = Disable
All information subject to change without notice. (Rev. 01/07)
Default
0 –
Disabled
0 –
Disabled