Detroit Diesel DDEC VI Application And Installation page 190

Table of Contents

Advertisement

INPUTS AND OUTPUTS
4.3.1
AGS2 BACKUP LAMP
This digital output is used for non-multiplexed applications with the AGS2 transmission.
Installation
This digital output circuit is designed to sink no more that 2.0 A (DC) current.
The AGS2 Backup Lamp is wired to pin 3/9 of the CPC.
Programming Requirements and Flexibility
The options for this digital output are listed in Table 4-28.
Parameter
Parameter
Group
3 09 DO
35
Selection
3 09 DO Fault
35
Detection
* Not supported in NAFTA
Table 4-28
AGS2 Backup Lamp Programming Options
4-30
Setting
0 – Disabled
1 — Grid Heater Hard Wired*
2 – AGS2 Backup Lamp
2 – AGS2 Backup
3 – Engine Brake Active
Lamp
4 – Not Used
5 — FUSO Engine Brake
Active Lamp*
0 – Disabled
1 – Enabled
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
Options
Default
0 – Disabled
0 – Disabled
All information subject to change without notice. (Rev. 01/07)
Access
VEPS or
DRS
VEPS or
DRS