4.3.9
ETHER START
This digital output is switched to ground when ether should be injected into the engine for cold
start purposes.
NOTE:
This output is used on a Series 60 engine only.
Installation
This function is wired to pin 31/8 of the 31-pin connector. The power supply for the ether system
should be wired to pin 31/22 of the 31-pin connector.
Programming Requirements & Flexibility
The options for this digital input are listed in Table 4-35.
Parameter
Parameter
Group
SW6
MCM – 1
Configuration
MCM – 8
Cold Start Type
Table 4-35
Ether Start Options
All information subject to change without notice. (Rev. 01/07)
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
Options
0 – Disable
24 – Ether Start
0 – No Function
1 – Grid Heater
3 – Ether Injection
Default
Access
0 - Disable
VEPS, DRS
0 – No Function
VEPS, DRS
4-37