EEC1 – Electronic Engine Controller #1
Transmission Rate:
Data Length:
Data Page:
PDU format:
PDU specific:
Default priority:
PGN:
Byte : 1
Status_EEC1
Bits: 8-5
Bits: 4-1
Byte: 2
Drivers Demand Engine - Pct Torque (SPN 512)
Resolution:
Byte: 3
Actual Engine - Percent Torque (SPN 513)
Resolution:
Bytes: 4,5
Engine Speed (SPN 190)
Resolution:
Byte: 6
Source address of controlling device for engine control (SPN 1483)
Byte: 7
Bits: 8–5
Bits: 1–4
All information subject to change without notice. (Rev. 01/07)
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
10 ms
8 bytes
0
240
4
3
61,444 (0x00F004)
Not Defined
Engine / Retarder Torque Mode (SPN 899)
0000: Low Idle Governor
0001: Accelerator Pedal
0010: Cruise Control
0011: PTO Governor
0100: Road Speed Governor
0101: ASR Control
0110: Transmission Control
0111: ABS Control
1000: Torque Limiting
1001: High Speed Governor
1010: Braking System
1011: Remote Accelerator - N/A
1100: Not Defined
1101: Not Defined
1110: Other
1111: Not Available
1% / Bit, -125% offset
1% / Bit, -125% offset
0.125 rpm / Bit, 0 rpm offset
Not Defined
Engine Starter Mode (SPN 1675)
0000: Start Not Requested
0001: Starter Active, Gear Not Engaged
0010: Starter Active, Gear Engaged
0011: Start Finished; Starter Not Active After Having Been Actively
Engaged
0100: Starter Inhibited Due To Engine Already Running
6-47