The CPC options for the single-speed fan – Type 7 are listed in Table 5-36.
Parameter
Parameter
Group
AC Fan Vehicle
19
Speed Enable
AC Fan Vehicle
19
Speed Thresh
Eng Brake Enable
19
Auto Fan
PTO Enable Auto
19
Fan Activation
Air Condition
19
Enable Auto Fan
J1939 Fan Request
19
Enable
19
Fan AC Hold Time
19
Hold Time Fan
Mode of AC Status
6
Input
Table 5-36
Single-speed Fan – Type 7 CPC Options
All information subject to change without notice. (Rev. 01/07)
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
Description
Enables/disables the
road speed threshold
for AC fan.
Road speed
threshold above
which the A/C fan
request is not using
the hold time
Enables/disables
turning on the fan
with engine brakes.
Enables/disables
turning on the fan
when the PTO is
active.
Enables/disables
turning on the
fan when the air
conditioning is on.
Enables the fan
based on a J1939
CM1 fan request.
Minimum fan on
time for AC
Minimum fan on time
0 = Disable
1 = AC Active Closed
Defines type of input
2 = AC Active Open
for A/C switch
3 = LIM Active Closed
4 = LIM Active Open
Options
Default
0 = Disable
0 = Disable
1 = Enable
0 – 250 km/h
32 km/h
0 = Disable
0 = Disable
1 = Enable
0 = Disable
0 = Disable
1 = Enable
0 = Disable
1 = Enable
1 = Enable
0 = Disable
0 = Disable
1 = Enable
0–600 sec
180 sec
0–600 sec
10 sec
2 = AC
Active Open
Access
VEPS,
DRS
VEPS,
DRS
VEPS,
DRS
VEPS,
DRS
VEPS,
DRS
VEPS,
DRS
VEPS,
DRS
VEPS,
DRS
VEPS,
DRS
5-59