Detroit Diesel DDEC VI Application And Installation page 356

Table of Contents

Advertisement

FEATURES
Remote PTO Programming Requirement and Flexibility
The Remote PTO parameters are listed in Table 5-76 and Table 5-77.
Parameter
Parameters
Group
Config PTO
7
Speed Control
Max PTO Spd
7
Resume Accel
Sw
Min PTO Spd
7
Set Coast Sw
PTO Throttle
7
Override
Enable
Throttle
7
Override Max
Eng Spd
PTO Dropout
7
Serv Brk Prk
Brk
PTO Dropout
7
Clutch Enabled
Table 5-76
Remote PTO Parameters (1 of 2)
5-144
Description
0 = Disabled
1 = Enabled
2 = Enabled if neutral
Enables/disables
3 = Enabled if neutral & park
the PTO function
brake
4 = Enabled if park brake
5 = PTO while driving
Sets the max
500 – 3000 RPM
PTO speed
Sets the min PTO
500 – 3000 RPM
speed
Enables/disables
0 = Disable PTO
the throttle pedal
1 = Enable engine speed in
from overriding
PTO mode to be increased
PTO mode.
with throttle pedal
Sets the max
engine speed
that the throttle
0 – 3000 RPM
can obtain when
in PTO mode.
0 = No PTO dropout with
Service Brake or Park Brake
Activation
Enables/Dis-
1 = PTO drops out if the
ables the status
Service Brake or Park Brake
of the Service
is being pressed
Brake or Park
Brake for dis-
2 =PTO drops out on Service
abling of PTO
Brake Activation
3 = PTO drops out on Park
Brake Activation
Enables/Dis-
0 = No PTO dropout with
ables the sta-
clutch pedal
tus of the Clutch
1 = Causes PTO to dropout if
Switch for dis-
clutch is being pressed
abling of PTO
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
Options
Defaults
0 = Disabled
3000 RPM
500 RPM
1 = Enable
3000 RPM
0 = No PTO
dropout with
Service Brake
or Park Brake
Activation
0 = No PTO
dropout with
clutch pedal
All information subject to change without notice. (Rev. 01/07)