INPUTS AND OUTPUTS
4.3.17
RED STOP LAMP
The Red Stop Lamp (RSL) is illuminated for all active serious faults, which require the engine to
be shutdown immediately. The AWL will also flash when an engine shutdown occurs.
Installation
This digital output circuit is designed to sink no more than 250 mA (DC) current.
The RSL is wired to pin 3/16 of the CPC.
NOTE:
This digital output is REQUIRED.
4.3.18
STARTER LOCKOUT
This digital output drives a normally closed relay which interrupts the starting signal when the
output has been activated.
Installation
This digital output circuit is designed to sink no more than 2.0 A (DC) current.
The Starter Lockout digital output is wired to pin 3/17 of the CPC.
Programming Requirements and Flexibility
The options for this digital output are listed in Table 4-42.
Parameter
Parameter
Group
3 17 DO
35
Selection
3 17
35
DO Fault
Detection
* Not supported in NAFTA
Table 4-42
Starter Lockout Programming Options
4-44
Setting
0 – Disabled
1 – Enable Starter Lockout
2 – Enable Kickdown Output*
3 – Not Used
1 – Enable Starter
4 – Optimized Idle Alarm
Lockout
5 – Split Valve*
6 – Starter Lockout and AGS2
Run Signal/Starter Lockout
7 – Engine Brake Disabled for
Overspeed*
0 — Disabled
1 — Enabled
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
Options
Default
0 – Disabled
0 – Disabled
All information subject to change without notice. (Rev. 01/07)
Access
VEPS or
DRS
VEPS or
DRS