Detroit Diesel DDEC VI Application And Installation page 407

Table of Contents

Advertisement

ATI2 - Aftertreatment Intake Gas 2
Transmission Repetition Rate:
Data Length:
Extended Data Page:
Data Page:
PDU format:
PDU specific:
Default priority:
PGN:
Bytes: 1–2
Exhaust Gas Temperature 1 (SPN 3241) – N/A
Bytes: 3–4
Particulate Trap Intake Gas Temperature (SPN 3242) (CPC Rel 2 or later)
Resolution:
Byte: 5
Exhaust Gas Temperature 1 Preliminary FMI (SPN 3243) – N/A
Byte: 6
Particulate Trap Intake Exhaust Gas Temperature Preliminary FMI – N/A
ATO2 - Aftertreatment Outlet Gas 2
Transmission Repetition Rate:
Data Length:
Extended Data Page:
Data Page:
PDU format:
PDU specific:
Default priority:
PGN:
Bytes: 1–2
Exhaust Gas Temperature 3 (SPN 3245) – N/A
Bytes: 3–4
Particulate Trap Outlet Gas Temperature (SPN 3246) (CPC Rel 2 or later)
Resolution:
Byte: 5
Exhaust Gas Temperature 3 Preliminary FMI (SPN 3247) – N/A
Byte: 6
Particulate Trap Outlet Exhaust Gas Temperature Preliminary FMI – N/A
All information subject to change without notice. (Rev. 01/07)
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
500 ms
8 bytes
0
0
253
180
6
64948 (0xFDB4)
0.03125°C / Bit, -273°C offset
500 ms
8 bytes
0
0
253
179
6
64947 (0xFDB3)
0.03125°C / Bit, -273°C offset
6-31