5.20.3
PROGRAMMING REQUIREMENTS AND FLEXIBILITY
The PasSmart parameters are programmable at engine order entry or with DDDL 7.0, Vehicle
Electronic Programming System (VEPS), and DRS as listed in Table 5-68.
Parameter
Parameter
Group
23
PasSmart Enable
PS Pass Speed
23
Duration
PS Pass Speed
23
Interval
PS Pass Speed
23
Increment
* The time within which the road speed limit will return to the programmed road speed limit when the
feature is deactivated.
Table 5-68
PasSmart Parameters
5.20.4
INTERACTION WITH OTHER FEATURES
PasSmart will increase the Vehicle Speed Limit.
A vehicle can be set up with both PasSmart and Fuel Economy Incentive, but the extra speed
increments provided by the two features do not add together. For example, if Fuel Economy
Incentive is set up to give 7 MPH of extra speed when the driver hits the maximum fuel economy
target and the PasSmart increase is 5 MPH the resulting speed increase is 7 MPH, not 12 MPH.
All information subject to change without notice. (Rev. 01/07)
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
Description
Enables/disables the feature.
The duration of time per
interval that is permitted at the
higher speed. A value of zero
will disable the feature.
The period of time when the
CPC resets to begin a new
period.
The additional vehicle
speed permitted above
the programmed vehicle
speed limit. A value of zero
will disable the feature.
Options
Default
0 = Disable
0
1 = Enable
0 to 255 minutes
0
1 to 24 hours*
8
0 to 250 KPH
0
Access
DDDL 7.0,
VEPS or DRS
DDDL 7.0,
VEPS or DRS
DDDL 7.0,
VEPS or DRS
DDDL 7.0,
VEPS or DRS
5-119