Parameter
Parameter
Group
Ambient Air
31
Temp Sensor
Enable
Lo Amb Air
17
Override
Temp
Hi Amb Air
17
Override
Temp
Idle Shudown
17
Auto Override
*Not supported in NAFTA
Table 5-49
Idle Shutdown Timer Programming Options
All information subject to change without notice. (Rev. 01/07)
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
Description
Configures the
ambient air temp
2 = Reserved for J1939
sensor.
3 = Reserved for J1587
4 = Reserved for ECAN
Extreme low
ambient air temp
to allow override.
Extreme high
ambient air temp
to allow override.
Enables auto
override of
0 = No automatic override
Idle/PTO
Shutdown based
1 = Automatic override performed
on ambient air
temperature.
Options
0 = Disabled
1 = Hardwired
0 = Disabled
-40°C – 75°C
-40°C – 75°C
0 = No automatic
performed
Default
Access
VEPS,
DRS
DDDL
-4°C
7.0, DRS,
VEPS
DDDL
75°C
7.0, DRS,
VEPS
DDDL
override
7.0, DRS,
performed
VEPS
5-95