Detroit Diesel DDEC VI Application And Installation page 209

Table of Contents

Advertisement

4.4
ANALOG OUTPUTS – CPC
The CPC has two analog outputs that can be used for various functions.
4.4.1
PIN 3/05 – ANALOG OUTPUT
This pin can be configured for the functions listed in Table 4-47.
Function
Oil Pressure Lamp
5 Bar Oil Pressure Gauge
10 Bar Oil Pressure Gauge
Table 4-47
Analog Output Selections for CPC Pin 3/05
4.4.2
PIN 3/06 – ANALOG OUTPUT
This pin can be configured for the functions listed in Table 4-48.
Function
Coolant Temp Lamp
Coolant Temperature Gauge
OI Thermostat
Table 4-48
Analog Output Selections for CPC Pin 3/06
All information subject to change without notice. (Rev. 01/07)
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
Description
This output will be turned on when MCM detects a pre-warning
or warning based on oil pressure.
The oil pressure will be converted to the proper pulse
width for a 5 Bar Oil Pressure Gauge.
The oil pressure will be converted to the proper pulse width
for a 10 Bar Oil Pressure Gauge.
Description
This output will be turned on when MCM detects a pre-warning
or warning based on coolant temperature.
The coolant temperature will be converted to the proper
pulse width for a coolant temperature gauge.
Can be used for the input for the OI thermostat.
Option
1
2
3
Option
1
2
3
4-49