5.1
ACCELERATION LIMITER
TBD
5.1.1
PROGRAMMING REQUIREMENTS AND FLEXIBILITY
The parameters and options for Acceleration Limiter are listed in Table 5-1.
Parameter
Parameter
Group
Noise Max
23
Engine Speed
Noise Min
23
Engine Speed
AL Min Engine
23
Torque
Enable Noise
23
Control
AL Ramp Up
23
Rate
Table 5-1
Acceleration Limiter Parameters and Options
All information subject to change without notice. (Rev. 01/07)
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
Description
Maximum engine
speed for noise
0 – 4000 rpm
trigger control
Minimum engine
speed for noise
0 – 4000 rpm
trigger control
Minimum engine
torque during
accelerations
Enable noise control
0 – VCU Style
function
1 – DDEC Style
Sets acceleration rate
0 – 8191 rpm/s
while in noise control
Options
Default
1600 rpm
1400 rpm
0 – 100%
100%
1 – DDEC
Style
160 rpm/s
Series
60
Access
Setting
1800
VEPS,
rpm
DRS
1350
VEPS,
rpm
DRS
VEPS,
15%
DRS
1 –
VEPS,
DDEC
DRS
Style
120
VEPS,
rpm/s
DRS
5-3