Acceleration Limiter - Detroit Diesel DDEC VI Application And Installation

Table of Contents

Advertisement

5.1

ACCELERATION LIMITER

TBD
5.1.1
PROGRAMMING REQUIREMENTS AND FLEXIBILITY
The parameters and options for Acceleration Limiter are listed in Table 5-1.
Parameter
Parameter
Group
Noise Max
23
Engine Speed
Noise Min
23
Engine Speed
AL Min Engine
23
Torque
Enable Noise
23
Control
AL Ramp Up
23
Rate
Table 5-1
Acceleration Limiter Parameters and Options
All information subject to change without notice. (Rev. 01/07)
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
Description
Maximum engine
speed for noise
0 – 4000 rpm
trigger control
Minimum engine
speed for noise
0 – 4000 rpm
trigger control
Minimum engine
torque during
accelerations
Enable noise control
0 – VCU Style
function
1 – DDEC Style
Sets acceleration rate
0 – 8191 rpm/s
while in noise control
Options
Default
1600 rpm
1400 rpm
0 – 100%
100%
1 – DDEC
Style
160 rpm/s
Series
60
Access
Setting
1800
VEPS,
rpm
DRS
1350
VEPS,
rpm
DRS
VEPS,
15%
DRS
1 –
VEPS,
DDEC
DRS
Style
120
VEPS,
rpm/s
DRS
5-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents