Detroit Diesel DDEC VI Application And Installation page 319

Table of Contents

Advertisement

There are three battery run modes: Normal Battery Run Mode, Alternate Battery Run Mode,
and Continuous Battery Run Mode.
Normal Battery Run Mode –While in normal battery run mode, all battery voltage Optimized
Idle starts are two hours long. This mode is customer selectable by setting the Alternate Time to
0, the default mode as listed in Table 5-57.
Alternate Time
Battery Time
0
Table 5-57
Normal Battery Run Mode
Alternate Battery Run Mode –This mode is allowed only when the Alternate Time is set to a
non-zero value. This parameter is customer selectable. While in Alternate Battery Run Mode, all
voltage starts are based on Alternate Time unless a critical battery restart event is detected. A
critical battery restart event is detected when the engine starts and runs to recharge the battery
for the alternate time and then detects another battery start within one hour after the engine
stops. At this point, the run time will change to two hours. The Alternate Battery Run Mode
parameters are listed in Table 5-58.
Alternate Battery
Battery Time
Run Time
a
(Customer
Selectable)
Table 5-58
Alternate Battery Run Mode
Continuous Battery Run Mode – In this mode, the engine continues to idle without shutting
down when two consecutive critical battery restart events have occurred. This feature is customer
selectable. The parameters for Continuous Battery Run Mode are listed in Table 5-59. A fault
code is logged when this move is initiated (PID 168 FMI 14).
Alternate
Battery Run
Battery Time
Time
0
2 Hours
a
(Customer
2 Hours
Selectable)
Table 5-59
Continuous Battery Run Mode
Oil Temperature - The engine will start when the oil temperature drops below 60°F (15.55°C)
and will run until the oil temperature reaches 104°F (40°C).
All information subject to change without notice. (Rev. 01/07)
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
Single Event
2 Hours
2 Hours
Single Event
2 Hours
a
Single Event
2 Hours
a
First
Consecutive
Event
2 Hours
First
Consecutive
Event
2 Hours
First
Second
Consecutive
Consecutive
Event
Event
2 Hours
Continuous
2 Hours
2 Hours
Second
Consecutive
Event
2 Hours
Second
Consecutive
Event
2 Hours
Further
Events
Continuous
Continuous