4.1.21
RPM FREEZE
The RPM Freeze input (when grounded) allows the operator to request that PTO maintain the
current engine speed. Locking on to a fixed engine speed is desirable in applications where the
input is subjected to electrical noise which in turn causes the engine speed to fluctuate. The
RPM Freeze Switch is normally open.
Installation
This input is wired to pin 4/18 on the CPC.
Programming Requirements & Flexibility
The options for this digital input are listed in Table 4-19.
Parameter Group
13
4 18 DI Selection
* Not supported in NAFTA
Table 4-19
RPM Freeze Programming Options
All information subject to change without notice. (Rev. 01/07)
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
Parameter
0 – Disable
1 — Enable Engine Door Bus*
2 — Enable Engine Hood
3 — AGS2 PTO Feedback
4 – RPM Freeze
5 — Engine Brake Disable
6 — Fast Engine Heat Up Switch
Options
Default
0 – Disable
Access
VEPS, DRS
4-21