4.3.5
CRUISE ACTIVE LAMP
When Cruise Control's Cruise Switch PTO is active, this digital output is switched to ground.
This digital output can be used to drive a lamp indicating the active state of Cruise Control.
NOTE:
This function is optional.
Installation
This digital output circuit is designed to sink no more that 250 mA (DC) current. The Cruise
Active Lamp is wired to pin 3/12 of the CPC.
Programming Requirements and Flexibility
The options for this digital output are listed in Table 4-31.
Parameter
Parameter
Group
35
3 12 DO Selection
3 12 DO Fault
35
Detection
* Not supported in NAFTA
Table 4-31
Cruise Active Lamp Programming Options
All information subject to change without notice. (Rev. 01/07)
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
Setting
Options
0 — Disabled
1 – Oil Level Lamp*
4 — Cruise
2 — AGS2 Check Trans Lamp
Active Lamp
3 — Oil Pressure Low Lamp
4 — Cruise Active Lamp
5 — FUSO Retarder Control 2*
0 — Disabled
1 — Enabled
Default
Access
VEPS or
0 — Disabled
DRS
VEPS or
0 — Disabled
DRS
4-33