TAPE AND TAPING

Tape must be used when conduit is utilized. Be sure to follow the tape manufacturers' guidelines.
The harness manufacturer may use tape under the harness covering (conduit or loom) to facilitate
harness building. Tape must be tightly wrapped at all conduit interconnections with a minimum of
two layers (refer to section 3.4). Be sure to firmly secure the start and finish ends of tape.
Criteria: Tape
Black vinyl electrical tape should not be used in applications
where the temperature exceeds 176°F (80°C).
In applications where the temperature doesn't exceed 176°F (80°C), black vinyl
electrical tape that is flame retardant and weather resistant may be used.
In applications where temperature exceeds 176°F (80°C), vinyl electrical tape should
not be used. For these applications, adhesive cloth backed, flame retardant polyethylene
or fiber glass tape (Delphi #PM-2203, Polikan #165 or equivalent) is recommended.
Criteria: Taping
The tape must extend a minimum of 1 in. (25 mm) past the conduit.
The tape must be crossed over butted conduit ends.
The tape must be extended a minimum of 1 in. (25 mm) in each direction at all branches.
All information subject to change without notice. (Rev. 01/07)