Optimized Idle Active Lamp; Optimized Idle Active Lamp Requirements And Guidelines; Programming Requirements And Flexibility - Detroit Diesel DDEC VI Application And Installation

Table of Contents

Advertisement

HARDWARE AND WIRING
3.7.11

OPTIMIZED IDLE ACTIVE LAMP

The Optimized Idle Active Lamp is controlled by DDEC VI..
The Optimized Idle Active Lamp remains ON:
□ For approximately five (5) seconds at the start of every ignition cycle
□ When Optimized Idle is active

Optimized Idle Active Lamp Requirements and Guidelines

The following requirements and guidelines apply to the Optimized Idle Active Lamp:
□ The Optimized Idle Active Lamp is optional.
□ A 12 volt light of less than 2.0 A (DC) is required depending on the ignition source. Digital
output circuits are designed to sink no more than 2.0 A (DC) current.
□ The Optimized Idle Active Lamp must be integrated into the instrument panel or placed in
clear view of the vehicle operator.
□ This output is wired to pin 4/09 of the CPC.

Programming Requirements and Flexibility

The options for this digital output are listed in Table 3-117.
Parameter
Parameter
Group
4 09 DO
35
Selection
4 09
35
DO Fault
Detection
* Not supported in NAFTA
Table 3-117
Optimized Idle Active Lamp Programming Options
3-118
(a bulb check)
Setting
0 = Disabled
1 = Accelerator Pedal Idle Position*
2 = Actual Torque*
3 = Road Speed*
4 = Engine Speed*
5 = Coolant Temp*
6 = Pedal Torque*
10 = OI
Active Lamp
7 = Boost Temp*
8 = Oil Pressure (MCM Threshold)*
9 = Coolant Temp (MCM Threshold)*
10 = OI Active Lamp
11 = Deceleration Lamp
12 = FUSO Ground Starter Lockout
Relay*
0 = Disabled
1 = Enabled
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
Options
All information subject to change without notice. (Rev. 01/07)
Default
Access
0 =
VEPS or
Disabled
DRS
0 =
VEPS or
Disabled
DRS