Detroit Diesel DDEC VI Application And Installation page 196

Table of Contents

Advertisement

INPUTS AND OUTPUTS
4.3.8
ENGINE BRAKE ACTIVE
This digital output is switched to ground whenever the Engine Brake is active. This digital output
could be used to drive an Engine Brake Active Lamp or give an engine brake active indication
to another vehicle system
NOTE:
This function is optional.
Installation
This digital output circuit is designed to sink no more than 2.0 A (DC) current.
Engine Brake Active is wired to pin 3/9 of the CPC.
Programming Requirements and Flexibility
The options for this digital output are listed in Table 4-34.
Parameter
Parameter
Group
3 09 DO
35
Selection
3 09
35
DO Fault
Detection
* Not supported in NAFTA
Table 4-34
Engine Brake Active Programming Options
4-36
Setting
0 – Disabled
1 – Grid Heater Hard Wired*
2 – AGS2 Backup Lamp
3 – Engine Brake
3 – Engine Brake Active
Active
4 – Not Used
5 – FUSO Engine Brake Active
Lamp*
0 — Disabled
1 — Enabled
7SA827 0701 Copyright © 2007 DETROIT DIESEL CORPORATION
Options
Default
0 – Disabled
0 – Disabled
All information subject to change without notice. (Rev. 01/07)