MG 1000B software installation
Perform the following procedure to configure the TLAN and ELAN network interfaces at the MG
1000B core and enable traffic over the LAN WAN.
Connecting the Ethernet ports
1. Insert the CAT5 cable into the RJ-45 10BaseT Port labelled ELAN on the front of the CP PM
Call Processor card.
Connect the other end of the CAT5 cable to the Ethernet switch. An alternative method is to
connect the CP PM ELAN port directly to the card on the CE port and then make the ELAN
connection from the 1E port of the card to the Ethernet switch.
For more information about the switch, see Avaya Converging the Data Network with VoIP
Fundamentals, NN43001-260.
This connects the MG 1000B Core to the ELAN network interface. The switch connects to
the LAN/WAN router.
2. Install and put the Signaling Server into operation, and connect the Signaling Server ELAN
and TLAN network interfaces to the switch. See
page 113.
For more detailed information on the switch and router connections, see Avaya Converging the Data
Network with VoIP Fundamentals, NN43001-260.

Using Element Manager to configure the node

In Element Manager, configure the following IP telephony node values that are specific to the MG
1000B:
• under H323 GW Settings (see
Gatekeeper
on page 147):
- Primary gatekeeper IP address
- Alternate gatekeeper IP address (if equipped)
- Primary Network Connect Server IP address
- Primary Network Connect Server Port number
- Alternate Network Connect Server IP address
- Alternate Network Connect Server Port number
- Primary Network Connect Server time-out
If NRS and NCS have different IP addresses, then the Branch Office must be configured as
non-RAS H.323 endpoint with NCS support in the NCS database.
The name of static H.323 endpoint should match H.323 ID field.
H.323 plays and important part in redirection. If there are no H.323 trunks, configure H.323
anyway.
Branch Office Installation and Commissioning
146
MG 1000B platform hardware installation
Figure 53: Confirm IP telephony node values for H.323