Use the following procedure to install ELAN and TLAN Ethernet ports on the back of a CS 1000M
UEM.
Important:
Installing ELAN and TLAN Ethernet ports on the back of a CS 1000M Universal Equipment
Module (UEM) is service-disrupting. Power to the shelf must be turned off during this procedure.
Installing ELAN and TLAN Ethernet ports on the back of a CS 1000M UEM
1. Obtain the special cabling kit (NTDW69AAE5) shipped with the CS 1000M model of the
Avaya CP PM Signaling Server (NTDW66AAE5).
The NTDW69AAE5 cabling kit should include the items shown in the following figure.
Figure 32: NTDW69AAE5 Cabling Kit contents
The following is a list of items in the NTDW69AAE5 cabling kit:
• two RJ-45 CAT5 Ethernet patch cables
• two Ethernet port couplers
• one Ethernet port adapter plate
• two screws
• two nuts
• two washers
• two ferrite beads
2. Insert an Ethernet port coupler into the adapter plate.
See the following figure.
June 2014
Branch Office Installation and Commissioning
Comments? infodev@avaya.com
Installing a Signaling Server
131