Avaya 1000 Installation And Commissioning Manual page 139

Branch office
Hide thumbs Also See for 1000:
Table of Contents

Advertisement

Figure 47: Securing CP PM hard drive to circuit board
4. Place Dip Switch S5 in position 2 to select HD Master option.
Figure 48: CP PM Signaling Server FMD dip switch
Important:
A CP PM circuit card has an on-board switch (S5) for designating the internal hard drive
(HD) or internal Compact Flash (CF) drive as the Fixed Media Device (FMD) for the
Signaling Server. You must configure the on-board FMD switch (S5) to position 2 to
designate the HD as the FMD for the Signaling Server.
5. Remove on-board compact flash retainer clip if populated.
Figure 49: CP PM Signaling Server internal CF card retainer clip
June 2014
Branch Office Installation and Commissioning
Comments? infodev@avaya.com
Installing a Signaling Server
139