Avaya 1000 Installation And Commissioning Manual page 125

Branch office
Hide thumbs Also See for 1000:
Table of Contents

Advertisement

Note:
The first step is applicable only when the Server card is used as a Call Server or Co-res
CS and SS.
Note:
Remove the retainer clip from the FMD slot when the CP PM card is used as a Signaling
Server. You must remove the clip to prevent it from shorting out adjacent cards.
2. Ensure that the FMD is correctly inserted and locked in place.
3. Insert the Server card.
• Slide the Server card into Slot 1 (or higher) of the MG 1000E cabinet or chassis.
• Slide the Server card into Slot 22 or 23 of the MG 1010 chassis.
4. Lock the card in place with the faceplate latches.
5. Connect the serial cable.
• For a MG 1000E or MG 1010 with Server cards in slots 1-10, connect the 2-port SDI
cable. The 50-pin Amphenol NTAK19EC connects to the back of the Server.
• For a MG 1010, connect a shielded CAT5 Ethernet cable to a NTC325AAE6 serial port
adapter. Connect this cable to the MGU faceplate port labelled TTY0 for CP1 or CP2. CP1
is for slot 22, CP2 is for slot 23.
• Connect the opposite end of the serial cable to the serial port on the maintenance
terminal.
Note:
To connect a terminal to the Server card with a NTAK19EC cable, complete the
following steps:
• Connect the NTAK19EC cable to the 50 pin MDF connector on the back of the desired
MG 1000E.
• Connect a 25 pin to 9 pin straight through serial cable to the 25 pin DB connector at the
end of the NTAK19EC cable (a female to female gender changer may be required). You
must povide this adapter.
• Connect the other end of the 25 pin to 9 pin straight through serial cable to the serial port
on the maintenance terminal.
June 2014
Branch Office Installation and Commissioning
Comments? infodev@avaya.com