Installing A Server Card Signaling Server - Avaya 1000 Installation And Commissioning Manual

Branch office
Hide thumbs Also See for 1000:
Table of Contents

Advertisement

MG 1000B platform hardware installation
Have you:
• an ECOS 1023 POW-R-MATE or similar type of multimeter
• appropriate cable terminating tools
• a computer (maintenance terminal) to connect directly to the Signaling Server, with:
- teletype terminal (ANSI-W emulation, serial port, 9600 bps)
- a web browser for Element Manager (configure cache settings to check for new web pages every time
the browser is invoked, and to empty the cache when the browser is closed)
Prepared the network data as suggested in Avaya Converging the Data Network with VoIP Fundamentals ,
NN43001-260 and Avaya Communication Server 1000E Planning and Engineering , NN43041-220 ?
Read all safety instructions in Avaya Communication Server 1000E Installation and Commissioning,
NN43041-310 ?

Installing a Server card Signaling Server

The CP PM and CP DC Signaling Server is a circuit card, and thus is not mounted in a rack. This
section contains instructions for installing a Server card Signaling Server in a MG 1000B system.
Installation in a MG 1000B system
The NTDW61 and NTDW99 models of the CP PM card are designed for use in a Avaya CS 1000E
system. The first task that must be performed is to install the CP PM hard drive shipped with the
server. For instructions, see
The MG 1000B platform must have a Signaling Server . The CP PM or CP DC Signaling Server can
be installed in the following card slots:
• Chassis NTDU14 slots 1-4
• Chassis NTDK91 slots 1-3
• Cabinet NTAK11 slots 1-10
• MG 1010 NTC310 slots 22-23
Warning:
Do not insert the NTDW61, NTDW99 model of the CP PM server or the NTDW53 model of the
CP DC server into any slot of a CS 1000M Universal Equipment Module (UEM). Doing so can
cause electrical shorts on adjacent circuit cards.
Installation in any Avaya Communication Server 1000M system
The NTDW66AAE5 model of the Avaya CP PM server is designed for use in a CS 1000M system.
The first task that must be performed is to install the hard drive shipped with the server. For
instructions see Circuit Card Reference Avaya Communication Server 1000, NN43001-311.
You can insert the NTDW66AAE5 model into any slot of a CS1000M; Universal Equipment Module
(UEM) except slot 7. The External Peripheral Equipment Controller (XPEC) is next to slot 7 and
prevents the double wide faceplate of the NTDW66AAE5 model from seating into slot 7.
The next task that you must perform is to install ELAN and TLAN Ethernet ports on the back of the
CS 1000M UEM. These ports are used to connect your Avaya CP PM Signaling Server to the ELAN
and TLAN Ethernet subnets of your CS 1000M system.
Branch Office Installation and Commissioning
130
Replacing the hard drive on a CP PM Signaling Server
Comments? infodev@avaya.com
on page 138.