Avaya 1000 Installation And Commissioning Manual page 106

Branch office
Hide thumbs Also See for 1000:
Table of Contents

Advertisement

Main office configuration
SIP_DOMAIN4 bell
SIP_DOMAIN5 bell
SERVER_IP1_1 47.11.25.183 --> set to appropriate value depending on SIPL
type
SERVER_IP1_2 47.11.25.181 --> set to appropriate value depending on SIPL
type
...
SERVER_PORT1_1 5070 --> set to appropriate value depending on SIPL type
SERVER_PORT1_2 5070 --> set to appropriate value depending on SIPL type
SERVER_RETRIES1 2 --> keep alive retry counter before switch over
SERVER_RETRIES2 2
...
#****************Device settings******************
FORCE_BANNER YES
BANNER SLG
UPDATE_USERS NO
SIP_PING YES --> set to YES for keep alive
.
AUTOLOGIN_ENABLE YES
# Time configuration
DST_ENABLED YES
TIMEZONE_OFFSET -18000
.
VMAIL 2300
VMAIL_DELAY 300
.
AUTO_UPDATE YES
AUTO_UPDATE_TIME 0
.
DEF_LANG English
MAX_INBOX_ENTRIES 50
MAX_OUTBOX_ENTRIES 50
MAX_REJECTREASONS 5
MAX_PRESENCENOTE 5
Branch Office Installation and Commissioning
106
Comments? infodev@avaya.com
June 2014

Advertisement

Table of Contents
loading

Table of Contents