Installing the server in a rack-mount or stackable setup

This topic provides information on setting up an S3400-H or S3210R server in a commercial cabinet in a rack-
mount configuration or stacked on top of one another in a desktop configuration. The S3210 server is only
supported in a tower configuration.
Identify the installation method to be used at your site, then see the appropriate section:
Installing the S3400-H server in a rack-mount configuration
!
Installing the S3210R server in a rack-mount configuration
!
Installing the server in a stackable desktop configuration
!
Caution! The Message Networking server is heavy. Get another person to assist you with lifting and placing the
server unit.
Installing the S3400-H server in a rack-mount configuration
The task describes how to install a server in a commercial cabinet. This is also called a rack-mount
configuration.
To install an S3400-H server into a rack:
Note: The server is typically installed directly above the UPS.
1. Place the server on a flat, stable surface.
2. If the mounting handles are not already attached, attach them now:
a. Connect the handles to the bracket using the supplied flat-head screws. See item 1 in
hardware for a rack-mounted
b. Align the mounting bracket with the screw holes on the side of the server and secure using the
supplied flat-head screws. See Item 2 in
3. The mounting rails consist of a narrow, flat piece that connects to the server, and a slide. Identify the rails
for the left and right side of the server as you face the unit from the front (the rack-mount rails are not
interchangeable). Some rails are labeled LH for left and RH for right.
If the set of rails you have is not labeled:
a. Hold the rail-slide assembly so that the 2-hole bracket that connects to the front of the customer
rack faces left. See Item 7 in
b. Fully extend the slide so that you can see the holes in the flat piece of the rail slide that mounts to
the server. See Item 4 in
If the holes are on the upper side of the flat rail piece, this rail connects to the right side of
#
the server chassis.
If the holes are on the lower side of the flat rail piece, this rail connects to the left side of the
#
server chassis.
Note: The holes for mounting to the unit are offset to get the correct alignment in the rack. Verify by the
position of the holes in the bracket that you are installing each rail on the correct side.
4. Attach the rack-mount rails to the server as follows:
a. Remove the two screws and retaining bar on the rail slide just before the server-retaining latch.
Set them aside for later. See Item 3 in
b. Disassemble the slide (necessary to access all three screw holes).
Message Networking Help
Admin
>
S3400-H.
Mounting hardware for a rack-mounted
Mounting hardware for a rack-mounted
Maintenance
Installing the servers
> Installing the server in a rack-mount or
Mounting hardware for a rack-mounted
Mounting hardware for a rack-mounted