DLP- D369 Clear a Manual or Force Switched Node Timing Reference

DLP-D369 Clear a Manual or Force Switched Node Timing Reference
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
In node view, click the Maintenance > Timing > Source tabs.
Step 1
Find the Clock reference that is currently set to Manual or Force in the Operation list.
Step 2
From the Operation drop-down list choose Clear.
Step 3
Click Apply.
Step 4
Click Yes in the confirmation dialog box. If the normal timing reference is an acceptable valid reference,
Step 5
the node switches back to the normal timing reference as defined by the system configuration.
If the normal timing reference is invalid or has failed, a warning message appears. Click OK; the timing
Step 6
reference does not revert.
Return to your originating procedure (NTP).
Step 7
DLP-D370 View Circuit Information
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Navigate to the appropriate CTC view:
Step 1
Click the Circuits tab. The Circuits tab shows the following information:
Step 2
Cisco ONS 15454 SDH Procedure Guide, R7.0
20-76
This task provides information about ONS 15454 SDH circuits.
None
DLP-D60 Log into CTC, page 17-49
As needed
Onsite or remote
Retrieve or higher
To view circuits for an entire network, from the View menu, choose Go to Network View.
To view circuits that originate, terminate, or pass through a specific node, from the View menu,
choose Go to Other Node, then choose the node you want to search and click OK.
To view circuits that originate, terminate, or pass through a specific card, in node view, double-click
the card containing the circuits you want to view.
Circuit Name—Name of the circuit. The circuit name can be manually assigned or automatically
generated.
This task clears a Manual or Force switch on a node timing reference and
reverts the timing reference to its provisioned reference.
None
DLP-D60 Log into CTC, page 17-49
As needed
Onsite or remote
Maintenance or higher
Chapter 20
DLPs D300 to D399
78-17194-01