Ntp- D190 Create A Unidirectional High-Order Circuit With Multiple Drops - Cisco ONS 15454 SDH Procedure Manual

Hide thumbs Also See for ONS 15454 SDH:
Table of Contents

Advertisement

Chapter 6
Create Circuits and Low-Order Tunnels
Click Finish. If the path does not meet the specified path diversity requirement, CTC shows an error
Step 19
message and allows you to change the circuit path. If you entered more than 1 in the Number of Circuits
field, the Circuit Creation dialog box appears after the circuit is created so you can create the remaining
circuits. Repeat Steps
When all the circuits are created, the main Circuits window appears. Verify that the circuits you created
Step 20
appear in the window.
Complete the following as necessary. Skip this step if you built a test circuit.
Step 21
a.
b.
Stop. You have completed this procedure.
NTP-D190 Create a Unidirectional High-Order Circuit with
Multiple Drops
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Complete the
Step 1
where you will create the circuit. If you are already logged in, continue with
If you want to assign a name to the tunnel source and destination ports before you create the circuit,
Step 2
complete the
automatically based on circuit type, node name, and sequence number, continue with
From the View menu, choose Go to Network View.
Step 3
Step 4
Click the Circuits tab, then click Create.
Step 5
In the Circuit Creation dialog box, complete the following fields:
Click Next.
Step 6
Define the circuit attributes:
Step 7
78-17194-01
6
through
Complete the
"NTP-D62 Test High-Order Circuits" procedure on page
Complete the
"NTP-D149 Test G-Series Circuits" procedure on page
This procedure creates a unidirectional STM-N circuit with multiple traffic
drops (circuit destinations).
None
NTP-D127 Verify Network Turn-Up, page 6-5
As needed
Onsite or remote
Provisioning or higher
"DLP-D60 Log into CTC" task on page 17-49
"DLP-D314 Assign a Name to a Port" task on page
Circuit Type—Choose VC_HO_PATH_CIRCUIT.
Number of Circuits—Leave the default unchanged (1).
Auto-ranged—Unavailable when the Number of Circuits field is 1.
Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters
(including spaces). Circuit names should be 44 characters or less if you want the ability to create
monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.

NTP- D190 Create a Unidirectional High-Order Circuit with Multiple Drops

18
for each additional circuit.
Cisco ONS 15454 SDH Procedure Guide, R7.0
6-66.
6-95.
at an ONS 15454 SDH on the network
Step
2.
20-7. If you want CTC to assign a name
Step
3.
6-63

Advertisement

Table of Contents
loading

Table of Contents