NTP- D144 Create an E-Series Single-Card EtherSwitch Manual Cross-Connect

If the circuit information is not correct, click the Back button and repeat the procedure with the correct
information. If the information is correct, check Route Automatically.
Note
Step 21
Click Finish.
Complete the
Step 22
Complete the
Step 23
page
Step 24
Complete the
To create additional circuits (spokes), repeat Steps
Step 25
Stop. You have completed this procedure.
NTP-D144 Create an E-Series Single-Card EtherSwitch Manual
Cross-Connect
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
In this procedure, cross-connect refers to a circuit connection created within the same node between the
Note
Ethernet card and an STM-N card that is connected to third-party equipment. You create cross-connects
at the source and destination nodes so that an Ethernet circuit can be routed from source to destination
across third-party equipment.
Complete the
Step 1
where you will create the circuit. If you are already logged in, continue with
If you want to assign a name to the circuit source and destination ports before you create the circuit,
Step 2
complete the
automatically based on circuit type, node name, and sequence number, continue with
Cisco ONS 15454 SDH Procedure Guide, R7.0
6-82
VLAN names
ONS 15454 SDH circuit nodes
You can also click Finish, delete the completed circuit, and start the procedure from the
beginning.
"DLP-D220 Provision E-Series Ethernet Ports" task on page
"DLP-D221 Provision E-Series Ethernet Ports for VLAN Membership" task on
19-19.
"NTP-D146 Test E-Series Circuits" procedure on page
This procedure manually creates a single-card EtherSwitch cross-connect
between E-Series Ethernet cards and STM-N cards connected to non-ONS
equipment.
E-Series Ethernet cards (E100T-G or E1000-2-G) must be installed at the
circuit source node.
NTP-D127 Verify Network Turn-Up, page 6-5
As needed
Onsite or remote
Provisioning or higher
"DLP-D60 Log into CTC" task on page 17-49
"DLP-D314 Assign a Name to a Port" task on page
Chapter 6
Create Circuits and Low-Order Tunnels
19-18.
6-89.
3
through 24.
at an ONS 15454 SDH on the network
20-7. If you want CTC to assign a name
Step
2.
Step
3.